久久久成人动漫_91欧美视频在线_另类国产ts人妖高潮系列视频_国产精品成人一区_一区二区精品在线_99视频在线

Scan code consultation:
0755-2102 2109
Technology
Technology
Current location: Home Technology Ex tech
Specific Requirements for Plastic Enclosures of Explosion proof Electrical Equipment - Shenzhen Zhongnuo Testing

SINO Testing Services

| 2023-03-10|Return

Limit requirements for surface resistance of non-metallic shells of explosion-proof equipment
In hazardous areas with explosive dust or gases, vapors, such as coal powder, flour, aluminum powder, hydrogen gas, etc., static electricity may cause fires or explosions, posing a high level of danger. Therefore, in explosive hazardous areas, the use of insulation materials should be minimized as much as possible. When choosing electrical insulation materials, it is advisable to consider maintaining a small insulation resistance to prevent discharge when non-metallic components come into contact with live parts. For non-metallic insulation materials, the anti-static ability of the equipment can be evaluated by measuring the surface resistance of the equipment casing.
Surface resistance, measured in ohms (Ω), refers to the resistance between two electrical elements in contact with a measured surface.


According to the requirements of IEC60079 series standards:


1. In Class II explosive gas environments, when the surface area of non-metallic enclosures of electrical equipment exceeds a certain limit value (as shown in Table 1), the surface resistance of the non-metallic material needs to be tested and verified to ensure that, by selecting materials, the surface resistance meets at least one of the following requirements when measured according to IEC 60079-0 26.13:
⑵ At ≤ 1 G Ω and (50 ± 5)% relative humidity;
⑵ At ≤ 100 G Ω and (30 ± 5)% relative humidity.


2. In Class III explosive dust environments, if the non-metallic shell surface area of electrical equipment does not exceed 500 square millimeters, the risk of static electricity may not be considered; If the limit is exceeded, surface resistance testing verification is required. The determination requirements are the same as the limit requirements for surface resistance testing in Class II gas environments mentioned above. For fixed installation equipment that cannot meet the surface resistance limit, the method of adding "X" after the explosion-proof mark and adding corresponding warning signs on the equipment can be adopted, and the user should be informed in the instruction manual.



Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 99视频有精品视频高清 | 亚洲成人精品视频 | 午夜影院操 | 久久久久夜色精品国产老牛91 | 欧美日韩精品不卡一区二区三区 | 看个毛片 | 羞羞电影在线观看www | 久啪视频 | 欧美精品一区自拍a毛片在线视频 | 久草网在线 | 国产精品麻豆91 | 久久精品一区二区三区不卡牛牛 | 久久男人天堂 | 国产精品999在线 | 久久777国产线看观看精品 | 国产在线区 | 国产人妖一区二区 | 久久久一区二区精品 | 亚洲影视在线观看 | 亚洲骚综合 | av色偷偷 | 九一免费版在线观看 | 最新精品在线 | 亚州精品在线视频 | 日日摸夜夜骑 | 精品国产乱码一区二区三区四区 | 中文字幕在线永久视频 | 国产精品亚洲激情 | 成人免费久久 | 蜜桃av鲁一鲁一鲁一鲁 | 色无极影院亚洲 | 色综合精品 | 色播视频在线播放 | 国产女同疯狂激烈互摸 | 久久久www成人免费精品 | 手机免费看一级片 | 超级av在线 | av在线免费观看国产 | 日本精品中文字幕 | 欧美精品一区自拍a毛片在线视频 | 片在线观看 |